Umbilical cord coiling abnormality as a predictor of maternal and fetal outcomes
Închide
Conţinutul numărului revistei
Articolul precedent
Articolul urmator
593 1
Ultima descărcare din IBN:
2020-05-26 09:07
Căutarea după subiecte
similare conform CZU
618.382-06:[618.33+618.5] (1)
Științe medicale. Medicină (11206)
SM ISO690:2012
ALSATOU, Alina. Umbilical cord coiling abnormality as a predictor of maternal and fetal outcomes. In: Moldovan Medical Journal, 2020, nr. 1(63), pp. 29-32. ISSN 2537-6373. DOI: https://doi.org/10.5281/zenodo.3685677
EXPORT metadate:
Google Scholar
Crossref
CERIF

DataCite
Dublin Core
Moldovan Medical Journal
Numărul 1(63) / 2020 / ISSN 2537-6373 /ISSNe 2537-6381

Umbilical cord coiling abnormality as a predictor of maternal and fetal outcomes

DOI:https://doi.org/10.5281/zenodo.3685677
CZU: 618.382-06:[618.33+618.5]

Pag. 29-32

Alsatou Alina
 
”Nicolae Testemițanu” State University of Medicine and Pharmacy
 
 
Disponibil în IBN: 11 martie 2020


Rezumat

Background: The umbilical cord forms connecting link between the fetus and placenta through which the fetal blood flows to and from the placenta. Its three blood vessels pass along the length of the cord in a coiled or helical fashion (spiral course). The aim of the study was to evaluate umbilical cord coiling abnormalities and determine its relationship with maternal and perinatal outcomes. Material and methods: The study included 190 patients divided into 2 groups: L1 – 95 patients with UC abnormalities and L0 – 95 with normal UC. The umbilical cord index was measured after delivery of the adnexal complex, which was defined as the total number of coils divided by the total length of the cord in centimeters. Results: The hypo- and hypercoiling umbilical cord suggests the high risk of fetal distress (p<0.0001), instrumental vaginal deliveries, the admission of the newborn in the neonatal intensive care (p<0.0001) and perinatal morbidity, which demanded a transfer to other medical facilities (p<0.05). UC torsion was associated with insufficiency of placental circulation, IUGR, fetal hypoxia and fetal mortality (p<0.05). The straight cord had significant correlation with maternal infections, antenatal mortality and preterm labor in anamnesis, placental insufficiency, IUGR and neonatal morbidity (p<0.05). Conclusions: Umbilical coiling index was found to be an important predictor of adverse maternal and perinatal outcomes. To conclude, abnormal umbilical coiling index is associated with an increased rate of adverse antenatal and neonatal features. The association shows wide variations in the numerous studies done so far.

Cuvinte-cheie
umbilical cord, coiling abnormality, straight cord, perinatal outcome