SM ISO690:2012 КОРНИЛЬЕВ, Алексей, БАРАНЕНКО, Александр, МАЛИНИНА, Ольга. Повышение эффективности применения абсорбционной холодильной машины для утилизации тепла когенерационных установок в схеме с использованием парокомпрессионной машины в качестве резервного источника холода. In: Problemele Energeticii Regionale, 2024, nr. 1(61), pp. 75-86. ISSN 1857-0070. DOI: https://doi.org/10.52254/1857-0070.2024.1-61.07 |
EXPORT metadate: Google Scholar Crossref CERIF DataCite Dublin Core |
Problemele Energeticii Regionale | ||||||
Numărul 1(61) / 2024 / ISSN 1857-0070 | ||||||
|
||||||
DOI:https://doi.org/10.52254/1857-0070.2024.1-61.07 | ||||||
CZU: 621.574.013-932.2 | ||||||
Pag. 75-86 | ||||||
|
||||||
Descarcă PDF | ||||||
Rezumat | ||||||
Cooling efficiency in a trigeneration cycles is one of the most frequently problems. A single-stage hot water absorption chiller is a universal solution for the gas engine waste heat utilization. How-ever, trigeneration centers exploitation experience shows the need for a more detailed technical and economic analysis to achieve maximum efficiency of the three-generation cycle. The purpose of this article is to substantiate the use of two-stage absorption cycles increasing the utilization rate of waste gas heat. The study presents the results of assessing the efficiency of using energy resources on the example of a three-generation center with more than 14 years of exploitation experience, including two single-stage absorption chillers (Q0= 0.65 MW each) and a chiller with a screw compressor (Q0= 0.8 MW). A comparison of actual energy consumption with designed indicators was carried out. The influ-ence of external and internal factors on the efficiency of heat recovery from a gas engine in single-stage absorption refrigeration machines with a water-heated generator is considered. The dependence of the change in the average annual cooling coefficient during the calendar year was obtained. Based on the study, proposals were formulated to improve the energy efficiency of refrigeration supply, giving an increase in refrigeration capacity of 6.1% with a commensurate reduction in the load on the screw chiller. The option of using a combined two-stage cycle chiller (type 2) under similar operating conditions showed a COP=1.43, which provides savings of 67.45 MWh of electricity or 5.4%, on an annualized basis (assuming only waste heat is used). Additional advantages of such a cycle include increased accu-racy and stability of maintaining the water temperature at the absorption chiller evaporator due to more flexible adjustment of the temperature of the lithium bromide solution in the high-temperature generator. |
||||||
Cuvinte-cheie energy efficiency, trigeneration cycle, absorption lithium bromide single-stage chiller, heat utilization, eficienţa energetică, ciclu de trei generări, răcitor cu o singură treaptă de bromură de litiu cu absorbție, utilizarea căldurii, нергетическая эффективность, тригенерационный цикл, абсорбционная бромистолити-евая одноступенчатая холодильная машина, утилизация теплоты |
||||||
|